Model 3001™ - 3006™ Digital Ton & Multiple Ton Cylinder General Specifications
General Specifications

5 year FULL warranty on ALL products!
| Indicator: | 4-1/2 Digit | 5 Digit | 1099™C.P.C. |
| Platform Size: | 45-1/2” (1156 mm) length x 24-1/4” (508 mm) width | ||
| Platform Height: | 8-1/2” (216 mm) from floor to top of 3 inch UHMW roller 9” (229 mm) from floor to top of 4 inch UHMW roller |
||
| Gross Capacity: | Up to 4000 lbs. (1814 kg) for each ton base — (150% overload protection is provided) | ||
| Accuracy: | 0.5% of full capacity | 0.1%-0.25% full capacity | |
| Resolution: | 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg) | ||
| 4-20mA:: | Standard on Channel 1, optional on Channel 2 - loop powered | Standard on Channel 1– loop powered (available for Channels 2 thru 4) |
|
| Level Indication/Relay Contacts: | (2) Standard | Optional – Up to 4 (as high, low or control) On one channel or more than one channel for a total of 4 set points with relay contact |
|
| Power: | 120VAC, 50/60 Hz, 0.3A 240VAC, 50/60 Hz, 0.15A | 85VAC to 265VAC | |
| Enclosure: | NEMA 4X, UL Approved Enclosure | ||
| Shipping Weight: | 110 lbs. | ||
Typical Specifications
Ton Cylinder Scale must be smaller than the cylinder and tilt up for cleaning and inspection. There must be a provision for securing weigh frame to floor. The profile shall be ultra low so as not to require a pit. There must be means to level the frame built into the scale frame. The load cell must be NTEP approved Stainless Steel shear beam cell with a built-in mechanical overload stop to protect it from damage during rough cylinder loading. The frame must be dry powder polyester plastic coated. The trunnions shall be corrosion proof with UHMW polyethylene rollers, requiring no maintenance or greasing. Axles shall be made of stainless steel.
Scale shall be a Model 3001 - 3006™ as manufactured by Scaletron Industries Ltd., Plumsteadville, PA.
STANDARD INDICATOR:
4-1/2 Digit LED indicator: Indicator must be electronic with digital display with characters 0.56 inches high and housed in a NEMA 4X, UL approved enclosure. An
output of 4-20 mA, 0-20 mA, or -8 to +12 mA, selectable as scale or loop powered to provide versatility to interface with related equipment, must be standard
equipment. Indicator comes with two low level relay contacts, standard. A knob to set tare weights is required. Indicator must be capable of 0.1 lb. or 0.1 kg up to
1000.0 lbs. or kg. Accuracy is 0.5% of full scale, or better.
OPTIONAL INDICATORS:
5 Digit LCD Indicator: Indicator must be electronic with a two line, backlit alphanumeric digital display with characters 0.56 inches high and housed in a NEMA 4X,
UL approved enclosure. Available as single or dual channel and capable of displaying two channels simultaneously. A loop powered programmable output of 4-20
mA and two set points per channel plus RS-232/485 communication ports, must be standard equipment. Indicator must be capable of 0.1 lb. or 0.1 kg up to 9999.0
lbs. or kg. Accuracy is 0.5% of full scale, or better.
Model 1099™ Chemical Process Controller see separate specification.