Model 3050™ Ton Cylinder Scale Conversion Kit
General Specifications

5 year FULL warranty on ALL products!
| Indicator: | 4-1/2 Digit | 5 Digit | 1099™C.P.C. |
| Platform Size: | 6” (152 mm) length x 5” (127 mm) width | ||
| Platform Height: | 3 inch (76.1 mm) from floor to top of load cell button – ADJUSTABLE | ||
| Gross Capacity: | Up to 4000 lbs. (1814 kg) for each ton base — (150% overload protection is provided) | ||
| Accuracy: | 0.5% of full capacity | 0.1%-0.25% full capacity | |
| Resolution: | 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg) | ||
| 4-20mA:: | Standard on Channel 1, optional on Channel 2 - loop powered | Standard on Channel 1– loop powered (available for Channels 2 thru 4) |
|
| Level Indication/Relay Contacts: | (2) Standard | Optional – Up to 4 (as high, low or control) On one channel or more than one channel for a total of 4 set points with relay contact |
|
| Power: | 120VAC, 50/60 Hz, 0.3A 240VAC, 50/60 Hz, 0.15A | 85VAC to 265VAC | |
| Enclosure: | NEMA 4X, UL Approved Enclosure | ||
| Shipping Weight: | 110 lbs. | ||
Typical Specifications
The load cell must be adjustable in height so conversion does not require alteration of existing frame. There must be a means to level the frame built into the conversion kit. The load cell must be NTEP approved Stainless Steel shear beam cell with a built-in mechanical overload stop to protect it from damage during rough cylinder loading. The load cell mount must be dry powder polyester plastic coated to provide protection from the harsh environment. The standard indicator must be electronic with a digital readout and housed in a NEMA 4x, UL approved fiberglass box. There shall be 4-20 mA, 0-20 mA and -8 to +12 mA output signals selectable as scale or loop powered to provide versatility to interface with related equipment. An adjustable low level contact closure is also required.
Scale shall be a Model 3050™ as manufactured by Scaletron Industries Ltd., Plumsteadville, PA.
STANDARD INDICATOR:
4-1/2 Digit LED indicator: Indicator must be electronic with digital display with characters 0.56 inches high and housed in a NEMA 4X, UL approved enclosure. An
output of 4-20 mA, 0-20 mA, or -8 to +12 mA, selectable as scale or loop powered to provide versatility to interface with related equipment, must be standard
equipment. Indicator comes with two low level relay contacts, standard. A knob to set tare weights is required. Indicator must be capable of 0.1 lb. or 0.1 kg up to
1000.0 lbs. or kg. Accuracy is 0.5% of full scale, or better.
OPTIONAL INDICATORS:
5 Digit LCD Indicator: Indicator must be electronic with a two line, backlit alphanumeric digital display with characters 0.56 inches high and housed in a NEMA 4X,
UL approved enclosure. Available as single or dual channel and capable of displaying two channels simultaneously. A loop powered programmable output of 4-20
mA and two set points per channel plus RS-232/485 communication ports, must be standard equipment. Indicator must be capable of 0.1 lb. or 0.1 kg up to 9999.0
lbs. or kg. Accuracy is 0.5% of full scale, or better.
Model 1099™ Chemical Process Controller see separate specification.