Model 4010™ Digital Tank Scale Specifications
General Specifications

5 year FULL warranty on ALL products!
| Indicator: | 3-1/2 Digit | 4-1/2 Digit | 5 Digit | 1099™C.P.C. |
| Platform Size: | 24”x24”, 30”x30”, 36”x36”, 48”x48” – custom sizes available | |||
| Platform Height: | 3-1/2” (89 mm) | |||
| Gross Capacity: | Up to 5000 lbs. (2268 kg) – custom capacities available (150% overload protection is provided) | |||
| Accuracy: | 0.5% of full capacity | 0.1%-0.25% full capacity | ||
| Resolution: | 0.1 up to 199.9, or 1.0 over 200 lbs. (kg) | 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg) | ||
| 4-20mA:: | Standard – scale or loop powered | Standard on Channel 1, Optional on Channel 2 – loop powered |
Standard on Channel 1– loop powered (available for Channels 2 thru 4) |
|
| Level Indication/Relay Contacts: | Optional | (2) Standard | Optional – Up to 4 (as high, low or
control) On one channel or more than one per channel for a total of 4 set points with relay contract |
|
| Power: | 85 VAC to 265 VAC | 120VAC, 50/60 Hz, 0.3A 240VAC, 50/60Hz, 0.15A |
85VAC to 265VAC | |
| Enclosure: | NEMA 4X, UL Approved Enclosure | |||
| Shipping Weight: | 24”x24” = 130 lbs.; 30”x30” = 150 lbs.; 36”x36” = 160 lbs.; 48”x48” = 240 lbs. | |||
Typical Specifications
The Tank Scale must have rugged steel frame and shall be dry powder polyester plastic coated. The decking shall be solid, 1/2 inch thick PVC. All hardware shall
be stainless steel. The height shall not exceed 3.5 inches so as not to require a pit or ramp. A stainless steel leveling foot shall be supplied with NTEP approved
stainless steel shear beam cell. There must be adjustable tank centering blocks in base.
Scale shall be a Model 4010™ as manufactured by Scaletron Industries Ltd., Plumsteadville, PA.
STANDARD INDICATOR:
3-1/2 Digit LCD Indicator: Indicator must be electronic with digital display with characters 0.5 inches high, with 0.1 lb. or 0.1 kg resolution and housed in a NEMA
4X, UL approved enclosure. Indicator is required to have 4-20 mA output selectable as scale powered or loop powered, standard. Indicator must have a knob to set
tare weight. Accuracy is 0.5% of full scale, or better.
OPTIONAL INDICATORS:
4-1/2 Digit LED indicator: Indicator must be electronic with digital display with characters 0.56 inches high and housed in a NEMA 4X, UL approved enclosure. An
output of 4-20 mA, 0-20 mA, or -8 to + 12 mA, selectable as scale or loop powered to provide versatility to interface with related equipment, must be standard
equipment. Indicator comes with two low level relay contacts, standard. A knob to set tare weights is required. Indicator must be capable of 0.1 lb. or 0.1 kg up to
1000.0 lbs. or kg. Accuracy is 0.5% of full scale, or better.
5 Digit LCD Indicator: Indicator must be electronic with a two line, backlit alphanumeric digital display with characters 0.56 inches high and housed in a NEMA 4X,
UL approved enclosure. Available as single or dual channel and capable of displaying two channels simultaneously. A loop powered programmable output of 4-20
mA and two set points per channel plus RS-232/485 communication ports, must be standard equipment. Indicator must be capable of 0.1 lb. or 0.1 kg up to 9999.0
lbs. or kg. Accuracy is 0.5% of full scale, or better.
Model 1099™ Chemical Process Controller see separate specification.