Model 4042WB-26x52™ Spill Containment Scale With Bladder Specifications
General Specifications

5 year FULL warranty on ALL products!
| Indicator: | 3-1/2 Digit | 4-1/2 Digit | 5 Digit | 1099™C.P.C. |
| Platform Size: | 26”x52” (30 gal.) – (85 gal. total with deployed bladder) – other sizes available | |||
| Platform Height: | 3-1/2 inch high (88.0mm) | |||
| Gross Capacity: | Up to 8000 lbs. (3629 kg) – other capacities available (150% overload protection is provided) | |||
| Accuracy: | 0.5% of full capacity | 0.1%-0.25% full capacity | ||
| Resolution: | 0.1 up to 199.9, or 1.0 over 200 lbs. (kg) | 0.1 up to 999.9, or 1.0 over 1000 lbs. (kg) | ||
| 4-20mA:: | Standard – scale or loop powered | Standard on Channel 1, Optional on Channel 2 – loop powered |
Standard on Channel 1– loop powered (available for Channels 2 thru 4) |
|
| Level Indication/Relay Contacts: | Optional | (2) Standard | Optional – Up to 4 (as high, low or
control) On one channel or more than one per channel for a total of 4 set points with relay contract |
|
| Power: | 85 VAC to 265 VAC | 120VAC, 50/60 Hz, 0.3A 240VAC, 50/60Hz, 0.15A |
85VAC to 265VAC | |
| Enclosure: | NEMA 4X, UL Approved Enclosure | |||
| Shipping Weight: | 100 lbs. | |||
Typical Specifications
The Integral Splash, Spill & Containment Scale must have rugged steel frame and shall be dry powder polyester plastic coated. The integral containment deck shall be solid polyethylene. (For Model 4042WB™ there must be enough floor space to allow the bladder to expand if there is a major spill). All hardware must be stainless steel. Scale frame height shall not exceed 1.5”. Total height depends on containment capacity. Load cells must be sealed in gasketed PVC enclosure. All 4 load cells shall be located outside the chemical containment basin to eliminate damage due to chemical spills. Indicator must be electronic with digital readout and housed in a NEMA 4X, UL approved fiberglass enclosure. There shall be a 4-20 mA output signal.
Scale shall be a Model 4042WB-26x52™ as manufactured by Scaletron Industries Ltd., Plumsteadville, PA.
STANDARD INDICATOR:
3-1/2 Digit LCD Indicator: Indicator must be electronic with digital display with characters 0.5 inches high, with 0.1 lb. or 0.1 kg resolution and housed in a NEMA
4X, UL approved enclosure. Indicator is required to have 4-20 mA output selectable as scale powered or loop powered, standard. Indicator must have a knob to set
tare weight. Accuracy is 0.5% of full scale, or better.
OPTIONAL INDICATORS:
4-1/2 Digit LED indicator: Indicator must be electronic with digital display with characters 0.56 inches high and housed in a NEMA 4X, UL approved enclosure. An
output of 4-20 mA, 0-20 mA, or -8 to + 12 mA, selectable as scale or loop powered to provide versatility to interface with related equipment, must be standard
equipment. Indicator comes with two low level relay contacts, standard. A knob to set tare weights is required. Indicator must be capable of 0.1 lb. or 0.1 kg up to
1000.0 lbs. or kg. Accuracy is 0.5% of full scale, or better.
5 Digit LCD Indicator: Indicator must be electronic with a two line, backlit alphanumeric digital display with characters 0.56 inches high and housed in a NEMA 4X,
UL approved enclosure. Available as single or dual channel and capable of displaying two channels simultaneously. A loop powered programmable output of 4-20
mA and two set points per channel plus RS-232/485 communication ports, must be standard equipment. Indicator must be capable of 0.1 lb. or 0.1 kg up to 9999.0
lbs. or kg. Accuracy is 0.5% of full scale, or better.
Model 1099™ Chemical Process Controller see separate specification.