GENERAL
SPECIFICATIONS
MODEL 1099 CHEMICAL PROCESS CONTROLLER
Previous
Page |
| CHANNEL: |
1
to 4 independent weighing channels
with independent input/output controls |
| INPUT: |
1
to 4 channels with a maximum of (16) 350 ohm load
cells. |
| DISPLAY
UNITS: |
Pounds,
kilograms, gallons or liters |
| RANGE: |
Zero
to a maximum reading of 99,999 |
| DISPLAY: |
LED
digital display of .56" high, one line,
for weight values. Backlit LCD aplphanumeric
display, two lines with 16 characters each |
| KEYBOARD: |
10
function keys and 10 numeric keys
Audible, tactile and visual confirmation |
| MEMORY: |
85
VAC to 265 VAC, 50/60 Hz
Redundant memory back-up, with a unique battery
and
solid state memory system. Resistant to interference
from pagers, cell phones, radios and other electronic
devices |
| CONNECTORS: |
Power
and Input sealed with plastic strain relief |
| ENCLOSURE: |
NEMA
4x, UL approved enclosure |
|
|
|
OPTIONS
- Loop
powered 4-20 mA signals: 1 - 4 separate signals outputting
either net weight or rate of feed, 400 ohms max. ( one 4-20
mA signal is standard, three more are optional)
- Set
points: A maximum of 4 set points on up to 4 channels. (1
on each channel or up to 4 on 1 channel)
- Serial
Ports: (1) RS232 Serial Port or (1) RS485 Serial Network
Port
- Audible
alarm
|
| TYPICAL
SPECIFICATIONS
Chemical Process Controller and “Indicator”
are considered synonymous for the purpose of bidding specifications.
The Indicator shall
be housed in a NEMA 4X, UL approved enclosure. Indicator shall
independently monitor up to 4 channels, with a maximum of
16 load cells per indicator, and also provide information
on the total of up to 4 channels. Each channel shall display
NET REMAINING, DAILY USAGE, TOTAL AMOUNT USED, RATE OF FEED,
DAYS UNTIL EMPTY, TARE WEIGHT, AND GROSS WEIGHT. A Data Log
Function shall store the DAILY USAGE for each of the previous
10 days. Digital Display shall have a 2 line, 16 characters
per line, alphanumeric LCD display at least 0.56” high
for weight value. Indicator shall have 10 numeric and 10 function
key pad with audible, tactile and visual confirmation, while
all operations are menu prompted for ease of use. Indicator
shall be capable of operating at power sources between 85VAC
and 265VAC. Indicator shall be virtually immune to interference
from commonly used electronic devices in the workplace, such
as pagers, cell phones and radios, or other electronic devices.
Indicator shall have a redundant memory back-up so that it
does not need to be reprogrammed in the event of a power loss.
Accuracy of indicator is 0.25% of full scale capacity, or
better.
|
5
year FULL warranty on ALL products.
Design improvements may be made without notice.
©2005 Scaletron Industries Ltd., Plumsteadville, PA Scaletron,
Scaletron Sets The Standard In Corrosion Resistance, Model
1099,
Model 2310, Model 2330, Model 2350, Model 2352-2353, Model
3001, Model 3002, Model 3003, Model 3004, Model 3005, Model
3006,
Model 3050, Model 4010, Model 4020, Model 4021, Model 4030,
Model 4040, Model 4040 IBC, Model 4041 and Model 5305 are
trademarks
of Scaletron Industries Ltd. Total Electronic System is a service
mark of Scaletron Industries Ltd. |
|