| Description |
Digital Scale Controller and Measurement System |
Digital Scale Controller and Measurement System |
Digital Scale Controller and Measurement System |
Digital Scale Controller and Measurement System |
| Interface |
Keypad with four (4) push buttons |
Encoder knob push/turn control |
Keypad with three (3) push buttons |
Touch screen |
| Accuracy |
±0.1% to ±0.25% of full scale capacity |
±0.1% to ±0.25% of full scale capacity |
±0.1% to ±0.25% of full scale capacity |
±0.1% to ±0.25% of full scale capacity |
| Display |
Backlit graphical LCD with up to 6 weight digits |
2 Line x 16 character alphanumeric/graphic backlit LCD with 6 digits for weight |
2 Line x 16 character alphanumeric/graphic backlit LCD with 6 digits for weight |
4.3" Alphanumeric/graphic color LCD touch screen display with adjustable brightness |
| Display Items |
Displays net or gross weight, display unit, tare, mA output signal (if applicable), and error status |
Displays net weight plus bar graph with net weight, gross weight and tare adjustment |
Displays net weight plus bar graph with net weight, gross weight and tare adjustment |
Displays net and gross weight; net and gross percent (%); net and gross weight bar graphs plus mA out, tare adjustment and set point values |
| Display Screens |
One (1) per channel |
One (1) single-channel and one (1) dual-channel weight display |
One (1) single-channel and one (1) dual-channel weight display |
Up to eleven (11) single-channel and five (5) dual-channel weight displays |
| Display Units |
Pounds, kilograms, gallons, or liters |
Pounds, kilograms, gallons or liters |
Pounds, kilograms, gallons or liters |
Pounds, kilograms, gallons or liters |
| Channels |
1 or 2 - One scale base per channel |
1 or 2 - One scale base per channel |
1 or 2 - One scale base per channel |
1 or 2 - One scale base per channel |
| Output Signal |
4-20 mA output per channel, based on net weight, scale or loop powered |
4-20mA Standard, 0-5V or 0-10V optional – 1 Output per channel, selectable as scale or loop powered |
4-20mA Standard, 0-5V or 0-10V optional – 1 Output per channel, scale or loop powered |
4-20mA Standard – 1 Output per channel, scale powered |
| Set Points |
|
2 or 4 Relay contacts optional per channel (high or low) - dry contact 3A relay with N.O and N.C connection |
2 or 4 Relay contacts optional per channel (high or low) - dry contact 3A relay with N.O and N.C connection |
2 or 4 Relay contacts optional per channel (high or low) - dry contact 3A relay with N.O and N.C connection |
| Remote Option |
Can be remotely mounted up to 200 feet from base frame |
Can be remotely mounted up to 200 feet from base frame |
Can be remotely mounted up to 200 feet from base frame |
Can be remotely mounted up to 200 feet from base frame |
| Audible Alarm |
|
78 dB internal piezo buzzer alarm with adjustable volume, external buzzer support |
78 dB internal piezo buzzer alarm with adjustable volume, external buzzer support |
Optional 78 dB internal piezo buzzer, external buzzer support |
| Communication Option |
|
|
|
Remote monitoring with either Modbus TCP through ethernet or Modbus RTU via RS-232/RS-485 serial network |
| Power |
100-250 VAC, 50/60 Hz, max 6 watts |
90/240 VAC, 50/60 Hz, 0.10/0.05A |
90/240 VAC, 50/60 Hz, 0.10/0.05A |
100/277 VAC, 50/60 Hz, 0.10/0.05A |
| Enclosure |
NEMA 4X, UL approved wall mount enclosure |
NEMA 4X, UL approved wall mount enclosure |
NEMA 4X, UL approved wall mount enclosure |
NEMA 4X, UL approved enclosure |
| Weight |
7 lbs. |
7 lbs. |
7 lbs. |
7 lbs. |